Automatic Bagging Packing Controller For Weighing Hopper Scale
Product Details:
Place of Origin: | China |
Brand Name: | Supmeter |
Certification: | CE |
Model Number: | BST106-M10[BH] |
Payment & Shipping Terms:
Minimum Order Quantity: | 1pcs |
---|---|
Price: | Negotiation |
Packaging Details: | 1pcs/box |
Delivery Time: | 3-10 working days |
Payment Terms: | T/T, Western Union |
Supply Ability: | 10000pcs per month |
Detail Information |
|||
Power Supply: | DC24V | Max. Connect: | 16Loadcells[350Ω] |
---|---|---|---|
Input: | 9DIs | Output: | 18DOs |
COM@COM1: | RS232 | COM2: | RS485 |
Highlight: | programmable load cell controller,load cell indicator |
Product Description
Automatic Bagging Packing Controller For Weighing Hopper Scale
Main Features:
- EMC design with high anti-jam for industrial environment.
- DC24V power input with reverse polarity protection
- Cortex-A8 CPU with 600MHz Clock, 128M RAM and 128M Flash.
- 7”[800x480] or10.2” [1024x600] TFT touch panel
-
24-bit ∑-△ADC with internal resolution 1/1,000,000
- High sampling frequency 800Hzer Packing] and Respective[Single-hopper Packing].
- Special Anti-vibration Digital Filtering Algorithm for precise weighing, stable display and rapid response.
- Auto Zero Tracking
- Fall Value Auto Correction.
- Auto Pause for Deviation Alarm.
- Auto Re-feed for Negative Deviation Alarm.
- Target Batch Count & Target Batch Weight Control.
- Definable DI/DO/AO/COM[Communication Port].
- 3-speed[high/medium/low] feeding control by DOs or AOs.
- Recipe Number: 100.
Technical Specification:
- Power Supply: DC24V±20%, Max. 10W.
- Loadcell Excitation Voltage/Current: DC5V/250mA.
- 16 Loadcells[350Ω] connectable.
- Weighing Signal Input Range: 0~12.5mV.
- 9 Normally Open Switch Inputs [DI].
- 18 Normally Open Transistor Outputs [DO]: DC24V, 500mA.
- 2 Analog Signal Outputs [AO]: 0~10V, Max.50mA.
- COM&COM1: RS232; COM2: RS485.
- USB1: Connect mouse, software download, data backup.
- LAN: Optional Ethernet.
- Outline Size [W×H×D]
- 7”: 226.5 × 163 × 36 mm.
- 10.2”: 274 × 193 × 40 mm.
- Panel Cut-out Size [W×H]
- 7”: 215 × 152 mm.
- 10.2”: 261 × 180 mm.
- Operating Temperature: -25℃~+45℃.
- Protection Level of Front Panel: IP65.
- Accuracy Grade: III.
- Verification Accuracy: 0.02%.
- Static Weighing Accuracy: 0.2%~0.5%.
- Packing Accuracy: 0.2%~0.5%
Software Function
- Manual Screen-locking/Screen-unlocking, Auto Screen-locking, Digital Setting&Calibration and I/O Testing functions available.
- Initial Zero Adjustment after Power-on, Auto Zero Tracking, Zero Fine Adjustment and Zero Calibration functions available.
- Load Calibration and Loss Calibration functions available.
- 10 Recipes for packing control.
- Optional ‘Fall Value Auto Correction’ function.
- Optional ‘Auto Pause for Deviation Alarm’ and ‘Auto Re-feed’ functions.
- Optional ‘Target Batch Control’ function [With Target Batch Count or Target Batch Weight finished, the packing process will stop automatically].
- The Batch Records can be printed automatically.
- Historical Batch Records, Totalizing Reports and Recipes can be queried and printed.
- With the multitasking mode, the weighing&control process will not be interrupted by parameter setting and the other operations.
Button Operation
Name | Operation | State Indicator | Authorization |
【Auto】 | Auto / Manual [Emergency Stop] switch. |
Green: Auto state. Grey: Manual state. |
All Users |
【Start】 | Start. |
Green: Running state. Grey: Stop state. |
|
【Re-run】 | Clear Alarm & Recover Running. | ||
【Last】 |
Last Batch [Normal Stop]. Stop after the present batch finished. |
Flashing Red. | |
【E-stop】 | Emergency Stop. | ||
【Alarm】 |
Alarm Query / Clear Alarm. ‘Auto/Pause’ state: Recover Running after clearing alarm. |
Red: Alarm state. | |
【Print】 |
Report Print:
|
||
【Lock】 |
Screen-locking: Locking/unlocking the operating buttons of main display interface. Auto Screen-locking: Refer to parameter [901]. |
Flashing Red: Locked. Grey: Unlocked. |
|
【Menu】 | Enter Main Menu. | ||
【User】 | User Login. Display: Operator / Engineer / Admin. | ||
【Zero】 | Zero Fine Adjustment [No Power-down Protection]. | Flashing green. | |
【Bag】 | Bag-clamp/release Request. |
Green: Bag-clamping state. Grey: Bag-releasing state. |
|
【High】 | Manual Start/Stop High-speed Feeding. | Green: Working state. | |
【Med】 | Manual Start/Stop Medium-Speed Feeding. | ||
【Low】 | Manual Start/Stop Low-speed Feeding. | ||
【Dump】 | Manual Start/Stop Dumping. | ||
【Clear】 | Clear Screen: Clear the display values of Feeding Weight, Totalized Weight, Batch Count and Packing Speed. |
Engineer Administrator |
Data Display & Quick Setting
Name | Description | Authorization |
Biggest Digits | Real-time Weight [Weight Unit]. | |
[HI] | Weight Upper Limit Alarm. | |
[OL] | Overload Alarm. | |
[CYCLES] | Batch Count. | |
[FINAL] | Final Feeding Weight. | |
[▲]/[HI] | Positive Deviation Alarm. | |
[▼]/[LO] | Negative Deviation Alarm. | |
[RUN] | Auto Running state. | |
[PAUSE] | Pause state. | |
[P_SW] | DI switch ‘Dumping Gate Closed in Place’ turned on. | |
[ZERO] | Weight ≤ Non-load Zero Range. | |
[STAB] | Weight is stable. | |
[FED] | Feeding Ended. | |
[FIN] | Target Batch [Count/Weight] Finished. | |
[SPLY] | In the process of ‘Supplying Material into Feeding Hopper’. | |
[LABEL]/[GAS]/ [SEW]/[CUT] |
In the process of ‘Labeling on Bag’ / ‘Filling Gas into Bag’ / Bag-sewing / Thread-cutting. | |
[RECIPE] | ‘Working Recipe’ Setting. | All Users |
[TARGET] | ‘Target Value’ Setting. | |
[SP1] | SP1 Lead Value for High-speed Feeding. | |
[SP2] | SP2 Lead Value for Medium-speed Feeding. | |
[FALL] | SP3 Fall Value for Low-speed Feeding. | |
|
||
[Mode] |
APP1.1 1-Hopper Mode / APP1.2 2-Hopper&1-Bag Mode / APP1.3 2-Hopper&2-Bag Mode / APP2.1 1-Bag Mode / APP2.2 2-Bag Mode. Refer to Parameter [300] ‘Application Mode’. |
|
[Au-supply DI] | ‘Material Auto-supply Permit ’ DI truns ON/OFF. | |
[Date&Time] | Date&Time. | |
[BAT. CNT] | Target Batch Count. | |
[SUM CYCLES] | Batch Count. | |
[BAT. WT] | Target Batch Weight. | |
[TOTAL] | Totalized Weight. | |
[CPM] | Packing Speed [Cycles/min]. |
Outline Size
Installation Mode
Terminal Diagram
Hopper-weighing with one Bag-clamping Mode:
Double-hopper-weighing with one Bag-clamping Mode:
System Diagram for APP3 Loss-in-weight Mode
Double-hopper-weighing with two Bag-clampings Mode: